KRECO Group - Power Solutions Business Division (New Website:www.ipsKRE.com)
    12V 1A 12W UL AC/DC adapter, switching adapter with F connector ▼
      product:12V 1A 12W UL AC/DC adapter, switching adapter with F connector
        KRECO P/N:KRE012SPS-1201R00UH
        DOWNLOAD / EMAIL NOW        
        Request a Quote: sales@kreco.com.cn
Details:
12VDC 1A series External wall-mount Switching Power Supply with F connector (Coaxial connector), Class II, Universal input, customized design.
P/N: KRE-SAW75
Model Number: KRE012SPS-1201R00UH

General: 12V 1,000mA series External wall-mount switching power supply with F connector, F connctor type AC/DC adapter









Power: 12W
AC Input: 100 to 240VAC 50/60Hz 0.28A
DC output : 12VDC/1A

Model Number:
 KRE-XXXYYYZ
"XXX"=030-480, The output voltage is DC3.0-48.0V,
"YYY"=001-450, The output current is 0.01-4.5A,
"Z" representing the input plug, 0-European plug, 1-British plug, 2-the Australian plug, 3-USA plug, 4-Japan plug, 5-China plug, 6-Korea plug.




Leakage current: 0.25mA maximum at 264V AC
MTBF: meet MIL-HDBK-217F over 50,000hrs, full load, 25°C
Burn-in Quality check: 100% checked at full load, 40℃, 4 hrs continously running
Withstanding voltage: 3kV 1minute 10mA max, between primary and secondary
Inrush current: 50A (maximum) at 240V (15A at 90V AC, 18A at115V AC, 31A at 230V AC, and 33A at 264V




CISPR22 Class B
CNS13438 Class B
FCC Part15 Class B
EN55022 Class B
EN55024/A1:2001
GB9254-1998/GB17625.1-2003
IEC61000-4-2; IEC61000-4-3
IEC61000-4-4; IEC61000-4-5
IEC61000-4-6; IEC61000-4-11
AS/NZS3548, AS/NZS4251.1 class B




No load input power (240V AC): 0.3W
Input voltage: 100 to 240VAC
Input frequency range: 50 to 60Hz
input current: 280mA maximum
Efficiency: 85% maximum
Inrush current (240V AC): 25A, cold 25°C




DC output voltage: 12V DC
DC output current: 1,000mA
Regulation: ±1% line, ±5% load
Ripple/noise: 120mV
Output voltage precision: 5%
Output connector: F coaxial Connector.




High reliability
LED indication
Low-temperature
Light and convenient plug-in
High efficiency: consumption, meet US Energy start/CEC/AS/MEPS/EUP/ERP




Storage: -20 to 65°C
Operating: 0 to 40°C




Storage: 10 to 95% RH
Operating: 10 to 95% RH




CE(Low Voltage Directive)
UL1310, GB4943-2001
EN60950:2009; EN60065
PSE IEC60950, EN60065
AS/NZS 60950:2000, AS/NZS60065




AC/DC power adapter protection:
Short-circuit protection
Over-voltage protection
Over temperature protection
Over-current protection